Manufacturer, Supplier & Exporter of Electroplating Chemicals and Metallic Salts including Nickel Sulphate Hexahydrate, Nickel Chloride Hexahydrate.
Manufacturer, Supplier & Exporter of Electroplating Chemicals and Metallic Salts including Nickel Sulphate Hexahydrate, Nickel Chloride Hexahydrate.
|
Toggle navigation
  • Home
  • Our Products
  • Our Gallery
  • Infrastructure Facilities
  • Download Broucher
  • About Us
  • Contact Us
  • Request a Quote

Cleaner Mse – 1111

  1. Home
  2. Cleaner Mse – 1111

Cleaner Mse – 1111

GENERAL PURPOSE SOAK AND ELECTROLYTIC CLEANER

CLEANER MSE-1111 IS A MEDIUM DUTY, HIGH DETERGENCY ALKALINE CLEANER FOR RAPID AND EFFICIENT CLEANING OF MOST METALS. THE CLEANER IS SO BUFFERED  AND INHIBITED THAT THERE IS LITTLE OR NO ATTACK  ON  THE METALS  NORMALLY  ENCOUNTERED  IN  THE  PLATING  ROOM,  WITH   THE EXCEPTION OF ALUMINUM.

IT  IS DESIGNED TO PERFORM THE FUNCTION OF A SOAK CLEANER AS  WELL AS  THOSE  OF AN ANODIC AND CATHODIC  ELECTROLYTIC  CLEANER.  THIS SHOULD BE CLASSIFIED AS A MEDIUM DUTY ALKALINE CLEANER, WHICH  CAN NOT  BE  USED  TO REMOVE HEAVY ACCUMULATIONS OF  OIL,  GREASE  AND BUFFING COMPOUNDS.

MAKE UP :

FILL  A  M.S. TANK APPROXIMATELY 2/3 FULL OF COLD WATER.  ADD  THE REQUIRED  AMOUNT  OF  CLEANER MSE-1111 AND  STIR  TO  DISSOLVE  THE MATERIAL. FILL TO FINAL VOLUME AND HEAT TO OPERATING TEMPERATURE.

OPERATION :

THE WORK IS IMMERSED IN THE CLEANER EITHER WITH OR WITHOUT THE USE OF  ELECTRIC CURRENT. IN MANY APPLICATIONS IT IS USED FIRST  AS  A SOAK  CLEANER  AND  THEN AS AN  ELECTROLYTIC  CLEANER.  THIS  DUAL FUNCTION CAN BE PERFORMED BY USING ONE OR TWO TANKS. DEPENDING  ON THE  NATURE  OF  THE  METAL BEING CLEANED, IT CAN  BE  USED  AS  A CATHODIC OR ANODIC CLEANER.

M.S.  ARTICLES ARE CLEANED ANODICALLY FOR 1-2 MINUTES  AT  CURRENT DENSITIES OF 40-60 AMPERES PER SQ. FT. AT CONCENTRATION OF  60-100 GM/LIT. WHILE COPPER IS CLEANED IN THE SAME MANNER AS M.S.

BRASS  CAN  BE  SOAK CLEANED OR CAN  BE  CATHODICALLY  CLEANED  AT CONCENTRATION  OF  50-70  GM/LIT AND CURRENT  DENSITIES  OF  25-50 AMPS/SQ.FT.  FOR  1-2  MINUTES  OR FOR AS  LONG  AS  NECESSARY  TO DISLODGE ANY SOLIDS. THEREAFTER, ANODIC CURRENT SHOULD BE USED FOR 5-10  SECONDS  AT  CURRENT  DENSITIES OF  10-30  AMPS  PER  SQ.FT. CATHODIC  CLEANING  SHOULD  ALWAYS BE  FOLLOWED  BY  BRIEF  ANODIC    CLEANING  IN  ORDER TO REMOVE ANY METALLIC FILMS  WHICH  MAY  HAVE     PLATED OUT CATHODICALLY.    LEAD  AND  SILVER  CAN BE CLEANED PRIMARILY BY SOAK  CLEANING  AND   FOLLOWED  BY A BRIEF PERIOD OF CATHODIC CLEANING, ANODIC  CLEANING SHOULD NOT BE EMPLOYED ON THESE METALS.

EQUIPMENT :

A  PLAIN WELDED M.S. TANK CAN BE USED. IT SHOULD BE EQUIPPED  WITH HEATING  COILS,ANODE  AND CATHODE RODS, AND A  CONTROLLABLE  POWER SOURCE.

CONTROL :

THE  CONCENTRATION  OF  THE CLEANER CAN BE  DETERMINED  BY  SIMPLE TITRATION  WITH  N/1  HYDROCHLORIC ACID USING  METHYL  RED  AS  AN INDICATOR BY TAKING 5 ML BATH SOLUTION.

CAUTION :CLEANER MSE-1111 IS ALKALINE IN NATURE AND CONTACT OF THE SALT OR

SOLUTION WITH THE SKIN OR EYES SHOULD BE AVOIDED.

 

CONCENTRATION 60-80 GM/LIT
TEMPERATURE 60-80* C
TIME 2-5 MINUTES
ELECTROLYTIC CLEANING
CONCENTRATION 60-100 GM/LIT
TEMPERATURE 50-70* C
TIME 10 SECONDS TO 2 MINUTES
CURRENT DENSITY 30-60 AMPS PER SQ. FT.
VOLTAGE 4-6 VOLT